Published January 30, 1995 | Version v1
Report Open

Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure. Revision 2

Description

This procedure checks that the shipment of the gauge to Hanford did not cause a failure. This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. Enraf-Nonius Series 854 level gauges are certified by Factory Mutual (FM) for National Fire Protectional Association (NFPA 70) hazardous Class 1, Division 1, Groups B, C, and D Locations. Its measuring principle is based on the detection of variations in the weight of a displacer suspended in the process fluid. The displacer is connected to a wire wounded on a precision measuring drum. A level change causes a change in the weight of the displacer which will be detected by the force transducer. Electronics within the gauge cause a servo motor to adjust the position of the displacer and compute the tank level based on the new position of the displacer drum. The gauge displays the level in decimal inches. An analog output signal transmits the level data for remote data processing

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95006907; NTIS; US Govt. Printing Office Dep.

Files

26045456.pdf

Files (579.8 kB)

Name Size Download all
md5:767c12def2599d2def3b657dbdc1fb3c
579.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
29 p.
Report number
WHC-SD---WM-ATP-077-Rev.2

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).