Requirements for characterization of DWPF canister welds and labels, and estimates of service life

Description

The Department of Energy has established specifications for the DWPF product, which require that the DWPF provide estimates of the service life of the canister label, provide assurance that the DWPF canister will be leaktight when shipped, demonstrate that the contents of the canistered waste form will not lead to internal corrosion of the canister. The DWPF has elected to meet these requirements, in part, by characterizing canisters produced in the facility during the Startup Test Program. This includes canisters filled on the pour turntable (normal conditions) and canisters filled on the drain turntable (credible upset conditions expected to be more severe due to higher temperatures). This document identifies the requirements for characterization of the canister fabrication welds and canister labels (characterization of canister closure welds is being performed by Equipment Engineering Section), and for estimation of their service life in DWPF's Glass Waste Storage Building

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE93009901; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
WSRC-RP--93-105

Optional Information

Contract/Grant/Project number
Contract AC09-89SR18035
Funding organization
USDOE, Washington, DC (United States).