Published February 1995 | Version v1
Report Open

Dose assessment of an accidental exposure at the IPNS

Description

Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95007706; NTIS; US Govt. Printing Office Dep.

Files

26050113.pdf

Files (2.3 MB)

Name Size Download all
md5:84a4ee105d9ffd4aff77fdc138648618
2.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
125 p.
Report number
ANL--ESH/HP-95-01

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26050113
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
EVALUATION; NEUTRON SOURCES; NUCLEAR FACILITIES; OCCUPATIONAL EXPOSURE; PERSONNEL; RADIATION ACCIDENTS; RADIATION DOSES
Descriptors DEC
ACCIDENTS; PARTICLE SOURCES; RADIATION SOURCES

Optional Information

Contract/Grant/Project number
Contract W-31109-ENG-38
Funding organization
USDOE, Washington, DC (United States).