Dose assessment of an accidental exposure at the IPNS
Description
Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95007706; NTIS; US Govt. Printing Office Dep.Files
26050113.pdf
Files
(2.3 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:84a4ee105d9ffd4aff77fdc138648618
|
2.3 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 125 p.
- Report number
- ANL--ESH/HP-95-01
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26050113
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- EVALUATION; NEUTRON SOURCES; NUCLEAR FACILITIES; OCCUPATIONAL EXPOSURE; PERSONNEL; RADIATION ACCIDENTS; RADIATION DOSES
- Descriptors DEC
- ACCIDENTS; PARTICLE SOURCES; RADIATION SOURCES
Optional Information
- Contract/Grant/Project number
- Contract W-31109-ENG-38
- Funding organization