A high-resolution two-dimensional 3He neutron MSGC with pads for neutron scattering experiments

  • 1. Graduate School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)
  • 2. Japan Atomic Energy Agency, Ibaraki (Japan)
  • 3. High Energy Accelerator Research Organization, Ibaraki (Japan)
  • 4. Graduate School of Engineering, Hokkaido University, Sapporo (Japan)

Description

High-resolution neutron imaging detectors are required for future high-intensity neutron sources such as the J-PARC project in Japan. We are developing a high-resolution gaseous neutron detector by using the microstrip gas chamber (MSGC) with floating-pad readout method. In this paper, we describe the neutron detector performance obtained with this MSGC and the readout method. For a 3 cmx3 cm MSGC filled with 5 bar CF4 and 0.5 bar 3He, we could achieve a measured position resolution of 0.6 mm (FWHM) including the beam size and the parallax error

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2007.06.057

Additional details

Identifiers

DOI
10.1016/j.nima.2007.06.057;
PII
S0168-9002(07)01317-4;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
580
Journal Issue
2
Journal Page Range
p. 1027-1030
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
3. international conference on imaging techniques in subatomic physics, astrophysics, medicine, biology and industry
Dates
27-30 Sep 2006
Place
Stockholm (Sweden)