Rapid-micro-determination of iodine in water

  • 1. Commissariat a l'Energie Atomique, Pierrelatte (France). Section protection

Description

A method is described for detecting one microgram of iodine per litre of water. After having tested manually volumetric and colorimetric methods, the authors chose a kinetic method. Reduction of arsenious oxide by ceric sulphate is catalyzed by the presence of small quantities of iodine. Failure of manual tests led to the adoption of a Technicon auto-analyzer for carrying out the determination; this improves the reproducibility of the method and gives a sensitivity of about 1 microgram of iodine per litre with an accuracy of ±15 per cent. (authors)

Availability note (English)

Available from INIS in electronic form

Abstract (French)

Une methode de detection du microgramme par litre de l'iode dans les eaux est decrite. Apres avoir teste manuellement des methodes volumetriques et colorimetriques, les auteurs ont choisi une methode cinetique. La reduction de l'anhydride arsenieux par le sulfate cerique est catalysee par la presence de petites quantites d'iode. Apres des essais manuels infructueux ce dosage est effectue au moyen d'un auto-analyseur Technicon, ce qui ameliore la reproductibilite de la methode et permet d'obtenir une sensibilite de l'ordre du microgramme par litre en iodure a ±15 pour cent pres. (auteurs)

Files

36090288.pdf

Files (1.1 MB)

Name Size Download all
md5:2f27aa053f964138c9042162156d8e72
1.1 MB Preview Download

Additional details

Additional titles

Original title (French)
Microdetermination rapide de l'iode dans les eaux

Publishing Information

Imprint Pagination
13 p.
Report number
CEA-R--3145