Published 1995
| Version v1
Journal article
Evaluation of potential hydrogen detonation due to postulated hydrogen pipe breaks
Description
This paper discusses a typical deterministic approach to address the hydrogen detonation issues contained in the U.S. NRC'c Commission's generic letter 93-06. This letter references a General Electric letter reported on under 10 CFR 21 regarding the potential for the rupture of a hydrogen supply line to the generator. Several BWR plants were evaluated
Additional details
Publishing Information
- Journal Title
- Transactions of the American Nuclear Society
- Journal Volume
- 72
- Journal Page Range
- p. 226.
- ISSN
- 0003-018X
- CODEN
- TANSAO
Conference
- Title
- Annual meeting of the American Nuclear Society (ANS).
- Dates
- 25-29 Jun 1995.
- Place
- Philadelphia, PA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27036506
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BWR TYPE REACTORS; EXPLOSIONS; FAILURES; HYDROGEN; REACTOR SAFETY
- Descriptors DEC
- ELEMENTS; ENRICHED URANIUM REACTORS; NONMETALS; POWER REACTORS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-950601--.