Published 2006 | Version v1
Journal article

Bayesian decision threshold, detection limit and confidence limits in ionising-radiation measurement

  • 1. Parkstrasse 11, D-38179 Schwuelper (Germany)
  • 2. Bayerisches Landesamt fuer Umwelt, Burgermeister-Ulrich-Strasse 160, D-86179 Augsburg (Germany)
  • 3. Gutenbergstrasse 22, D-52428 Juelich (Germany)
  • 4. Forschungszentrum Juelich, D-52425 Juelich (Germany)
  • 5. Forschungszentrum Karlsruhe, Fortbildungszentrum fuer Technik und Umwelt FTU, D-76021 Karlsruhe (Germany)
  • 6. Zentrum fuer Strahlenschutz und Radiooekologie, Universitaet Hannover, Am Kleinen Felde 30, D-30167 Hannover (Germany)

Description

Based on Bayesian statistics and the Bayesian theory of measurement uncertainty, characteristic limits such as the decision threshold, detection limit and limits of a confidence interval can be calculated taking into account all sources of uncertainty. This approach consists of the complete evaluation of a measurement according to the ISO Guide to the Expression of Uncertainty in Measurement (GUM) and the successive determination of the characteristic limits by using the standard uncertainty obtained from the evaluation. This procedure is elaborated here for several particular models of evaluation. It is, however, so general that it allows for a large variety of applications to similar measurements. It is proposed for the revision of those parts of DIN 25482 and ISO 11929 that are still based on conventional statistics and, therefore, do not allow to take completely into account all the components of measurement uncertainty in the calculation of the characteristic limits. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncl095

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
121
Journal Issue
1
Journal Page Range
p. 52-63
ISSN
0144-8420

Conference

Title
EURADOS 2006 annual meeting and scientific symposium on Uncertainties in Dosimetry - Principles Through to Practice
Dates
26 Jan 2006
Place
Chilton (United Kingdom)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
France
INIS RN
44021976
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALGORITHMS; CALIBRATION; EVALUATION; IONIZING RADIATIONS; ISO; SENSITIVITY; STATISTICAL MODELS; STATISTICS
Descriptors DEC
INTERNATIONAL ORGANIZATIONS; MATHEMATICAL LOGIC; MATHEMATICAL MODELS; MATHEMATICS; RADIATIONS

Optional Information

Notes
37 refs