Published June 1980 | Version v1
Report

Equipment match plateout and activity measurements at Three Mile Island

Description

Prior to decontamination and personnel entry into the TMI Unit 2 containment, the radiation sources must be defined. As part of this effort, a series of dose rate and photon spectrum measurements were made outside the equipment hatch. These measurements were analyzed to provide a preliminary estimate of the magnitude and isotopic distribution of plateout activity on the 305 elevation. The upper and lower bound estimates of this activity are presented

Additional details

Publishing Information

Imprint Title
Thermal reactor safety
Journal Page Range
p. 1188.
Report number
CONF-800403--(Vol.2)

Conference

Title
ANS thermal reactor safety meeting.
Dates
8 - 11 Apr 1980.
Place
Knoxville, TN, USA.