Published August 20, 1986 | Version v1
Miscellaneous

Measurement of contamination and decontamination properties of protective surfaces at nuclear power plants

Creators

  • 1. Vyzkumny Ustav Pozemnich Staveb, Prague (Czechoslovakia). Radioisotopove Oddeleni

Description

A method was developed for objective assessment of suitability of protective coatings for surfaces in nuclear power plants with respect to their consisting in standard contamination of the tested surface with isotope In-113m and its decontamination using an agreed upon method. A GAMMA scintillation system from Hungary is used for activity counting. The decontamination solution consists of 20 g oxalic acid, 20 g amonium oxalate, 10 ml nitric acid, 10 ml phosphoric acid, 20 ml of a detergent, and distilled water to complete 1 litre. The results of the measurement are processed using a Varian 620/L computer. (Z.M.)

Part of:
Collection of lectures delivered at decontamination course

Additional details

Additional titles

Original title (Czech)
Mereni kontaminovatelnosti a dekontaminovatelnosti ochrannych povrchu jadernych elektraren

Publishing Information

Imprint Title
Collection of lectures delivered at decontamination course
Imprint Pagination
94 p.
Journal Page Range
p. 41-50.
Report number
INIS-mf--10948

Optional Information

Notes
Imprint:Sbornik referatu prednesenych na dekontaminacnim kurzu.