Published August 20, 1986
| Version v1
Miscellaneous
Measurement of contamination and decontamination properties of protective surfaces at nuclear power plants
Creators
- 1. Vyzkumny Ustav Pozemnich Staveb, Prague (Czechoslovakia). Radioisotopove Oddeleni
Description
A method was developed for objective assessment of suitability of protective coatings for surfaces in nuclear power plants with respect to their consisting in standard contamination of the tested surface with isotope In-113m and its decontamination using an agreed upon method. A GAMMA scintillation system from Hungary is used for activity counting. The decontamination solution consists of 20 g oxalic acid, 20 g amonium oxalate, 10 ml nitric acid, 10 ml phosphoric acid, 20 ml of a detergent, and distilled water to complete 1 litre. The results of the measurement are processed using a Varian 620/L computer. (Z.M.)
Additional details
Additional titles
- Original title (Czech)
- Mereni kontaminovatelnosti a dekontaminovatelnosti ochrannych povrchu jadernych elektraren
Publishing Information
- Imprint Title
- Collection of lectures delivered at decontamination course
- Imprint Pagination
- 94 p.
- Journal Page Range
- p. 41-50.
- Report number
- INIS-mf--10948
INIS
- Country of Publication
- Serbia and Montenegro
- Country of Input or Organization
- Serbia and Montenegro
- INIS RN
- 18069029
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- AQUEOUS SOLUTIONS; DECONTAMINATION; EFFICIENCY; NUCLEAR POWER PLANTS; PAINTS; PROTECTIVE COATINGS; SIMULATION; SURFACE CLEANING; SURFACE CONTAMINATION; SURFACES; TESTING
- Descriptors DEC
- CLEANING; COATINGS; CONTAMINATION; DISPERSIONS; HOMOGENEOUS MIXTURES; MIXTURES; NUCLEAR FACILITIES; POWER PLANTS; SOLUTIONS; SURFACE FINISHING; THERMAL POWER PLANTS
Optional Information
- Notes
- Imprint:Sbornik referatu prednesenych na dekontaminacnim kurzu.