Published November 1981 | Version v1
Report

Correlation between Charpy Test Results and those from Larger Specimens and Structures on the Basis of General yield

  • 1. BAM, Berlin (United Kingdom)

Description

The authors discuss whether the instrumented Charpy test (with notched or pre-cracked specimens) is a suitable instrument to determine the general yield temperature of structures. Thus, they investigate the parameters of interest which may influence this temperature. Experiments are performed on a micro-alloyed fine grained normalized structural steel (StE 460 according to German standard). These experiments are performed on wide plate specimens, single edge notched three point bending specimens, and Charpy specimens. Results are discussed

Part of:
Proceedings of a C.S.N.I. specialist meeting on instrumented pre-cracked Charpy testing

Additional details

Publishing Information

Imprint Title
Proceedings of a C.S.N.I. specialist meeting on instrumented pre-cracked Charpy testing
Imprint Pagination
489 p.
Journal Page Range
p. 435-449
Report number
NEA-CSNI-R--1981-67

Conference

Title
C.S.N.I. specialist meeting on instrumented pre-cracked Charpy testing
Dates
1-3 Dec 1980
Place
Palo Alto, CA (United States)

Optional Information

Notes
10 refs.