Optical investigation of new pulsed magnet installation in KEK e-/e+ injector LINAC

  • 1. High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan)

Description

SuperKEKB injector Linac is performing continuous injection to SuperKEKB e-/e+, PF, and PF-AR ring. For high quality beam required in SuperKEKB rings, pulsed magnets were installed in the Linac and the number of the pulsed magnets are still not enough. Especially, there is not pulsed quadrupole magnet in around capture section after e+ generation target. In this section, not only e+ beam but also e- beam is transported. Therefore, beam optics for e- is disturbed, while that for e+ beam is optimized. It is difficult to replace all DC magnets to pulsed magnets because of both limited budget and personnel. We performed optical study to squeeze β function after e+ generation target by the minimum number of pulsed quadrupole magnets. (author)

Availability note (English)

Available from https://www.pasj.jp/web_publish/pasj2021/proceedings/PDF/TUP0/TUP033.pdf
Part of:
Proceedings of the 18th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (Japanese)
KEK電子陽電子入射器におけるパルス電磁石導入の光学的検討

Publishing Information

Imprint Title
Proceedings of the 18th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
[998 p.]
Journal Page Range
p. 511-513

Conference

Title
18. annual meeting of Particle Accelerator Society of Japan
Acronym
PASJ2021
Dates
9-12 Aug 2021
Place
Japan (Japan)

Optional Information

Notes
2 refs., 9 figs., 1 tab. Imprint:This symposium was held online