The temperature dependence of G-values for aqueous solutions irradiated with a 23 MeV 2H+ beam

  • 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

Description

Computer simulation of water radiolysis in the primary heat transport system of a nuclear power reactor requires, among other things, the g-values of eaq-, OH, H, H2, and H2O2 formed in the fast neutron radiolysis of water at 280o-325oC. These g-values cannot be easily measured directly. However, they can be estimated from a knowledge of the g-values for radiations which have linear energy transfer values characteristic of that found in a reactor. We report on an experimental technique for irradiating water samples at elevated temperatures with ion beams and present some g-values for irradiations with a 23 MeV deuteron beam. (author)

Part of:
Water chemistry of nuclear reactor systems 6. V. 1

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London (United Kingdom)
ISBN
0-7277-1697-2
Imprint Title
Water chemistry of nuclear reactor systems 6. V. 1
Imprint Pagination
228 p.
Journal Page Range
p. 79-84.

Conference

Title
6. international conference on water chemistry of nuclear reactor systems.
Dates
12-15 Oct 1992.
Place
Bournemouth (United Kingdom).