Published April 15, 1982 | Version v1
Miscellaneous

A new method for the calculation of the dose distribution around cylindrical gamma sources and the application for the computation of isodose plans for gynaecological radium-226 and iridium-192 applicators

Description

The method is based on an analytical representation of the non-exponential decrease of the Ra γ-radiation as a function of platinum layer thickness. The shielding function allows a direct integration of the Siewert integral. Thus exact numerical calculations of the dose become feasible for linear sources. Computer-based isodose distributions for tissue are presented for 56 Ra-applicators from the Goettingen isodose collection. (DG)

Availability note (English)

Available from the library of Goettingen Univ. (Germany, F.R.).

Abstract (German)

Das Verfahren beruht auf einer analytischen Darstellung der nicht-exponentiellen Schwaechung der γ-Strahlung des Ra in Abhaengigkeit von der durchstrahlten Platin-Schichtdicke. Die Schwaechungsfunktion erlaubt die direkte Integration des Sievert-Integrals. Dadurch werden exakte numerische Berechnungen der Dosisleistung von linearen Quellen moeglich. Fuer 56 Ra-Applikatoren aus dem Goettinger Isodosenatlas werden computerberechnete Isodosenblaetter fuer Gewebe wiedergegeben. (DG)

Additional details

Additional titles

Original title (German)
Ein neues Verfahren zur Berechnung der Dosisverteilung um umschlossene zylinderfoermige Gammastrahler und dessen Anwendung zur Erstellung von Isodosenplaenen um gynaekologische Radium-226- und Iridium-192-Applikatoren mittels eines Computerprogramms

Publishing Information

Imprint Pagination
155 p.