Published 2015 | Version v1
Miscellaneous

Effect Of Small Doses On THE Thymus In Pediatric Chest X - Ray

  • 1. Children Hospital Srebrnjak, Zagreb (Croatia)
  • 2. Rudjer Boskovic Institute, Zagreb (Croatia)
  • 3. Clinical Hospital Center Zagreb, Zagreb (Croatia)

Description

The thymus, pyramid-shaped lymphoid organ is immediately beneath the breastbone at the level of the heart, therefore chest X-ray covers the position of thymus. The thymus is divided into two lobes, lying on either side of the midline of the body. Unlike most other lymphoid structures, the thymus grows rapidly and attains its greatest size relative to the rest of the body during fetal life and the first years after birth. The thymus is a specialized organ of the immune system. It has big responsibility helping the body protect itself against autoimmunity diseases. It is well known from literature data that thymus size reduced at radiotherapy irradiation. After many years of experience in X-ray chest diagnostics with children a fairly regular thymus size reduction after exposure to diagnostic low doses was noticed. Therefore it was analysed at what percentage of children patients their control radiograms would exhibit a thymus shade decrease compared to the primary image taken at the illness out-set. In the Children Hospital Srebrnjak in one year 1972 children in the age group 0 - 5 years underwent X-ray exam. In our earlier study at PA and profile projections of lung examinations of this age group 0.15 mSv and 0.11 mSv average doses were measured on the back and on the chest, respectively. From this group the radiograms of those 119 children were analysed who were exposed, according to medical indication, to control examinations. 58 of the investigated patients showed enlarged thymus at the first exam. It could be seen from the control radiogram that 52 children of these 58 patients had significant or discrete decrease in size of thymus. Taking into account that thymus has very important role in maturity of T-lymphocytes and development of immunology tolerance these empiric statements are important for radiation protection of children in X-ray diagnostic of chest. (author).

Part of:
Proceedings of 10th Symposium of the Croatian Radiation Protection Association

Additional details

Identifiers

Publishing Information

Imprint Place
Zagreb (Croatia)
Imprint Title
Proceedings of 10th Symposium of the Croatian Radiation Protection Association
Imprint Pagination
429 p.
Journal Page Range
p. 195-200
ISSN
1849-5060
Report number
INIS-HR--16003

Conference

Title
10. Symposium of the Croatian Radiation Protection Association
Dates
15-17 Apr 2015
Place
Sibenik (Croatia)

INIS

Country of Publication
Croatia
Country of Input or Organization
Croatia
INIS RN
47111741
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CHEST; DOSES; PEDIATRICS; THYMUS; X RADIATION
Descriptors DEC
BODY; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; LYMPHATIC SYSTEM; MEDICINE; ORGANS; RADIATIONS

Optional Information

Notes
9 refs.; 1 tab.; 2 figs.