Published July 1988
| Version v1
Journal article
Microcomputer system of treatment of chamber stereophotographs using CCD pickups
Description
A microcomputer system for the treatment of track chamber stereophotographs is described. A CCD 1200 is used as a scanning pickup (photosensitive cell is 15 μm wide). The calibration measurement gives an accuracy of the particle track point coordinate pickup of δ=3.75 μm. (orig.)
Additional details
Publishing Information
- Journal Title
- Comput. Phys. Commun.
- Journal Volume
- 50
- Journal Issue
- 1/2
- Series
- Comput. Phys. Commun.
- Journal Page Range
- 213-215
- ISSN
- 0010-4655
- CODEN
- CPHCB
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 19093643
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; BUBBLE CHAMBERS; CALIBRATION; CAMAC SYSTEM; CHARGE-COUPLED DEVICES; COMPUTER NETWORKS; GAS TRACK DETECTORS; IMAGE PROCESSING; MICROPROCESSORS; PARTICLE TRACKS; PHOTOGRAPHY; READOUT SYSTEMS; SIGNAL-TO-NOISE RATIO; SPARK CHAMBERS; SPATIAL RESOLUTION
- Descriptors DEC
- ELECTRONIC CIRCUITS; MEASURING INSTRUMENTS; MICROELECTRONIC CIRCUITS; RADIATION DETECTORS; RESOLUTION; SEMICONDUCTOR DEVICES