Spectrographic determination of impurities in uranium tetrafluoride

Description

A carrier distillation method for the determination of Ag, Al, As, B, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Pb, and Si in uranium tetrafluoride was develop ped. the previous addition of 25% Y23 prevents the excitation of uranium by conversion of the volatile UF4 into U308 during the arc discharge. NaCl or Ga203, containing Ge and V as internal standards, are used as carriers, and samples are arced in 10 Amp. d.c. arc in a graphite anode cup. 7 mm diameter, 10 mm deep, being the weight of charge 300 mg. (Author) 14 refs

Availability note (English)

Available from INIS in electronic form

Files

40045005.pdf

Files (959.5 kB)

Name Size Download all
md5:6df3a4d01da70154d943ec69dedb5335
959.5 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Determinacion espectrografica de impurezas en tetrafluoruro de uranio

Publishing Information

Imprint Pagination
20 p.
Report number
JEN--192