Published June 1995 | Version v1
Journal article

99mTc-MIBI scintigraphy for the detection of parathyroid lesions in patients with hyperparathyroidism

  • 1. Toranomon Hospital, Tokyo (Japan)

Description

The usefulness of 99mTc-MIBI scintigraphy for the detection of parathyroid lesions was evaluated in 17 patients with hyperparathyroidism. Delayed image was used to evaluate the lesions. Detectability of MIBI for parathyroid lesions was 86% (18/21). The smallest lesion detected was parathyroid hyperplasia weighted 270 mg. Ectopic parathyroid adenoma and bone metastases of parathyroid carcinoma were clearly demonstrated. Detectability of MIBI scintigraphy for the lesions including ectopic and metastatic lesions was the highest among those of ultrasonography, CT and MRI methods. MIBI scintigraphy was thought to be useful for the detection of parathyroid lesions, especially for ectopic and metastatic lesions. (author)

Additional details

Publishing Information

Journal Title
Kaku Igaku
Journal Volume
32
Journal Issue
6
Journal Page Range
p. 557-562.
ISSN
0022-7854
CODEN
KAIGBZ