Published June 2013 | Version v1
Book

Work Breakdown Structure and Work Packages for Decommissioning the Nuclear Research Reactor VVR-S Magurele-Bucharest

Creators

Description

The research reactor type VVR-S (tank type, water cooled, moderator and reflector, thermal power 2 MW, thermal energy 9.52 GWd) was put into service in July 1957, and in December 1997, was shut down. In 2002, the Romanian Government decided to put the research reactor into a permanent shutdown condition in order to start decommissioning. This nuclear facility had been used in nuclear research and radioisotope production for 40 years without any events, incidents or accidents. At the same site, in the immediate vicinity of the research reactor, there are many other nuclear facilities: a radioactive waste treatment plant, a tandem Van de Graaff heavy ion accelerator, a cyclotron, an industrial irradiator and a radioisotope production centre.

Part of:
Safety Assessment for Decommissioning

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (International Atomic Energy Agency (IAEA))
ISBN
978-92-0-141410-6
Imprint Title
Safety Assessment for Decommissioning
Imprint Pagination
151 p.
Journal Issue
no. 77
Series
Safety Reports Series
Journal Page Range
p. 101-104
ISSN
1020-6450

Optional Information

Secondary number(s)
STI/PUB--1604