Published May 3, 2004 | Version v1
Report

An Analytical Technique to Determine the Potential for Moisture Accumulation in Deactivated Structures

Description

This paper describes an analytical technique developed to predict an order of magnitude volume of moisture accumulation in massive structures after deactivation. This work was done to support deactivation of a Department of Energy nuclear materials processing facility. The structure is a four-story, concrete building with a rectangular footprint that is approximately 250m long by 37m wide by 22m high. Its walls are 1.2m thick. The building will be supplied with unconditioned ventilation air after deactivation. The objective of the work was to provide a cost effective engineering evaluation to determine if the un-conditioned ventilation air would result in condensate accumulating inside the building under study. The analysis described is a simple representation of a complex problem. The modeling method is discussed in sufficient detail to allow its application to the study of similar structures

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/823532-TboXnN/native/

Additional details

Publishing Information

Imprint Pagination
[vp.]
Report number
WSRC-TR--2004-00179

Conference

Title
2004 ASME Heat Transfer/Fluids Engineering Conference
Dates
11-15 Jul 2004
Place
Charlotte, NC (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
35050604
Subject category
S99: GENERAL AND MISCELLANEOUS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COMPUTERIZED SIMULATION; CONDENSATES; DEACTIVATION; EVALUATION; MOISTURE; NUCLEAR FACILITIES; VENTILATION
Descriptors DEC
SIMULATION

Optional Information

Contract/Grant/Project number
AC--09-96SR18500
Funding organization
US Department of Energy (United States)