Description
Radon detectors based on an electrostatic collection of polonium and detection of its alpha decay are a popular choice for the measurement of radon activity. Due to the nature of 222Rn decays, 88% of radon progeny have a positive charge, thus enabling their collection on an electrode. A simulation software focused on the drift and diffusion of ions in an electric field has been developed, providing a tool to study and characterise such detectors. It has been found that one such device achieves only 44% collection efficiency, caused by the loss of a large fraction of the ions before reaching the collection diode. An improvement of the design is therefore proposed, changing the placement of the sensor resulted in an simulated increase of the collection efficiency up to 93%. Preliminary measurements performed using prototypes of these detectors confirm the results of the simulations. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncac134Additional details
Identifiers
- DOI
- 10.1093/rpd/ncac134;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 198
- Journal Issue
- 9-11
- Journal Page Range
- p. 791-795
- ISSN
- 0144-8420
Conference
- Title
- 42. Conference Days of Radiation Protection
- Dates
- 8-12 Nov 2021
- Place
- Prague (Czech Republic); Bratislava (Slovakia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 53096416
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALPHA DECAY; COMPUTER CODES; COMPUTERIZED SIMULATION; DESIGN; EFFICIENCY; ELECTRIC FIELDS; ELECTRODES; ELECTROSTATICS; MONTE CARLO METHOD; POLONIUM; POLONIUM IONS; PROGENY; RADIATION DETECTION; RADON; RADON 222; SENSORS
- Descriptors DEC
- ALPHA DECAY RADIOISOTOPES; CALCULATION METHODS; CHARGED PARTICLES; DAYS LIVING RADIOISOTOPES; DECAY; DETECTION; ELEMENTS; EVEN-EVEN NUCLEI; FLUIDS; GASES; HEAVY NUCLEI; IONS; ISOTOPES; METALS; NONMETALS; NUCLEAR DECAY; NUCLEI; RADIOISOTOPES; RADON ISOTOPES; RARE GASES; SIMULATION
Optional Information
- Notes
- 21 refs.