Published August 2022 | Version v1
Journal article

Monte Carlo simulation of polonium ion collection in electrostatic field for the purpose of radon detector development

  • 1. Faculty of Nuclear Sciences and Physical Engineering, CTU in Prague, Brehova 78/7, 115 19 Prague (Czech Republic)

Description

Radon detectors based on an electrostatic collection of polonium and detection of its alpha decay are a popular choice for the measurement of radon activity. Due to the nature of 222Rn decays, 88% of radon progeny have a positive charge, thus enabling their collection on an electrode. A simulation software focused on the drift and diffusion of ions in an electric field has been developed, providing a tool to study and characterise such detectors. It has been found that one such device achieves only 44% collection efficiency, caused by the loss of a large fraction of the ions before reaching the collection diode. An improvement of the design is therefore proposed, changing the placement of the sensor resulted in an simulated increase of the collection efficiency up to 93%. Preliminary measurements performed using prototypes of these detectors confirm the results of the simulations. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncac134

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
198
Journal Issue
9-11
Journal Page Range
p. 791-795
ISSN
0144-8420

Conference

Title
42. Conference Days of Radiation Protection
Dates
8-12 Nov 2021
Place
Prague (Czech Republic); Bratislava (Slovakia)

Optional Information

Notes
21 refs.