Published 1987
| Version v1
Journal article
Simple determination of low power on reflected reactors using the Feynman-α experiment
Creators
- 1. JAERI, Tokai, Ibaraki (Japan)
- 2. Hokkaido Univ., Sapporo (Japan)
- 3. Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.
Description
When a low power meter for a reactor is calibrated by using the Feynman-α method, the absolute power is obtained by the product of the power deduced from the one-point reactor formula and the g-factor which was introduced as the spatial correction factor on the Rossi-α measurement. In this paper, for the purpose of experimental usage, formulae of the g-factor for the different geometries are derived by one speed approximation and its characteristics are systematically surveyed. A simple formula of the g-factor for a spherical core is presented and applied. This formula can estimate the value of the g-factor with appropriate accuracy. (author)
Additional details
Publishing Information
- Journal Title
- Ann. Nucl. Energy
- Journal Volume
- 14
- Journal Issue
- 12
- Series
- Ann. Nucl. Energy.
- Journal Page Range
- 673-676
- ISSN
- 0306-4549
- CODEN
- ANEND
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 19078350
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- FEYNMAN METHOD; NEUTRON DIFFUSION EQUATION; NEUTRON FLUX; NEUTRON TRANSPORT; REACTOR KINETICS
- Descriptors DEC
- KINETICS; NEUTRAL-PARTICLE TRANSPORT; RADIATION FLUX; RADIATION TRANSPORT