Published July 2009 | Version v1
Journal article

Neutron spectrum measurement using rise-time discrimination method

  • 1. China Inst. for Radiation Protection, Taiyuan (China)
  • 2. Department of Engineering Physics, Tsinghua Univ., Beijing (China)
  • 3. The University of Tokyo, Tokyo (Japan)
  • 4. China Inst. of Atomic Energy, Beijing (China)

Description

PSD method can be used to measure the fast neutron spectrum in n/γ mixed field. A set of assemblies for measuring the pulse height distribution of neutrons is built up,based on a large volume NE213 liquid scintillator and standard NIM circuits,through the rise-time discrimination method. After that,the response matrix is calculated using Monte Carlo method. The energy calibration of the pulse height distribution is accomplished using 60Co radioisotope. The neutron spectrum of the mono-energetic accelerator neutron source is achieved by unfolding process. Suggestions for further improvement of the system are presented at last. (authors)

Additional details

Publishing Information

Journal Title
Radiation Protection (Taiyuan)
Journal Volume
29
Journal Issue
4
Journal Page Range
p. 219-224, 231
ISSN
1000-8187

Optional Information

Notes
7 figs., 6 refs.