A formal Flow-Accelerated Corrosion (FAC) program has been in place at Millstone Point Unit 2 since 1991. In spite of this, the unit experienced a pipe break in a heater drain pump recirculation line in August 1995. The failure occurred during a water hammer event in a straight, 8 inch pipe that had experienced wall thinning as the result of FAC. This paper describes the pipe rupture and the thermal hydraulic events that resulted in wall thinning as well as the thermal hydraulic conditions that initiated a water hammer with a pressure spike of sufficient magnitude to rupture the thinned pipe. Also discussed are the programmatic and organizational aspects surrounding the failure and the actions taken to prevent a similar occurrence
Additional details
Publishing Information
- Publisher
- American Society of Mechanical Engineers.
- Imprint Place
- New York, NY (United States)
- ISBN
- 0-7918-1785-7
- Imprint Title
- Pressure vessels and piping codes and standards: Volume 1. PVP-Volume 338
- Imprint Pagination
- 295 p.
- Journal Page Range
- p. 181-188.
Conference
- Title
- American Society of Mechanical Engineers (ASME) pressure vessels and piping conference.
- Dates
- 21-26 Jul 1996.
- Place
- Montreal (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 28019037
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CIRCULATING SYSTEMS; EROSION; FAILURE MODE ANALYSIS; FEEDWATER HEATERS; MILLSTONE-2 REACTOR; MITIGATION; PIPES; RUPTURES; THICKNESS
- Descriptors DEC
- DIMENSIONS; ENRICHED URANIUM REACTORS; FAILURES; HEATERS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-960706--.