Published 1992 | Version v1
Miscellaneous Open

Location of leakages in the fresh water primary network distribution in the Nuclear Center

  • 1. Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico)

Description

In the hydraulic net of Nuclear Centre in Salazar, Mexico was necessary the application of radioactive traces after very much efforts for locating the situation of leaks of water and not obtain satisfactory results for other methods. It was injected a small quantity of 24 Na2CO3 in aqueous solution in the tank discharge which stores the fresh water. After the running water movement was followed for gamma radiation detection omitted by the 24 Na in grave digged each 100 meters along the pipes. In this work is presented the methodology used to locate two water leaks and the corresponding safety radiological considerations. (Author)

Files

24064047.pdf

Files (126.6 kB)

Name Size Download all
md5:5dfd5b42f54dd49be1566a776d21964a
126.6 kB Preview Download
Part of:
6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 10: industrial applications of radiation and control

Additional details

Additional titles

Original title (Spanish)
Ubicacion de fugas en la red primaria de distribucion de agua potable en el Instituto Nacional de Investigaciones Nucleares

Publishing Information

Publisher
Instituto Nacional de Investigaciones Nucleares.
Imprint Place
Salazar (Mexico)
Imprint Title
6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 10: industrial applications of radiation and control
Imprint Pagination
89 p.
Journal Page Range
[8 p.].
Report number
INIS-mf--13619

Conference

Title
6. Seminar of the IIE-ININ-IMP on technological specialities.
Original Conference Title
6. Seminario IIE-ININ-IMP sobre especialidades tecnologicas
Dates
15 Jul 1992.
Place
Salazar (Mexico).

Optional Information

Notes
Imprint:6. Seminario IIE-ININ-IMP sobre especialidades tecnologicas. Mesa 10: aplicaciones industriales de la radiacion y control.