Published June 2010 | Version v1
Journal article

Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T

  • 1. Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany)
  • 2. University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany)
  • 3. Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany)
  • 4. Chair of Structural Statics and Dynamics, RWTH Aachen, Aachen (Germany)
  • 5. MRI, NHS Grampian, Aberdeen Royal Infirmary, Aberdeen (United Kingdom)
  • 6. Humboldt-University, Working Group Cardiovascular MR, Franz-Volhard-Klinik, Department of Cardiology, HELIOS-Klinikum Berlin-Buch and Charite Campus Buch, Berlin (Germany)

Description

As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n = 14). Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct R-wave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects - even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived from VCG-triggered acquisitions (1.5 T: ESVVCG = (56 ± 17) ml, EDVVCG = (151 ± 32) ml, LVMVCG = (97 ± 27) g, SVVCG = (94 ± 19) ml, EFVCG = (63 ± 5)% cf. ESVACT = (56 ± 18) ml, EDVACT = (147 ± 36) ml, LVMACT = (102 ± 29) g, SVACT = (91 ± 22) ml, EFACT = (62 ± 6)%; 3.0 T: ESVVCG = (55 ± 21) ml, EDVVCG = (151 ± 32) ml, LVMVCG = (101 ± 27) g, SVVCG = (96 ± 15) ml, EFVCG = (65 ± 7)% cf. ESVACT = (54 ± 20) ml, EDVACT = (146 ± 35) ml, LVMACT = (101 ± 30) g, SVACT = (92 ± 17) ml, EFACT = (64 ± 6)%). ACT's intrinsic insensitivity to interference from electromagnetic fields renders it suitable for clinical CMR. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-009-1676-z

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
20
Journal Issue
6
Journal Page Range
p. 1344-1355
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
41076552
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARDIOVASCULAR DISEASES; COMPARATIVE EVALUATIONS; ELECTROCARDIOGRAMS; NMR IMAGING
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DIAGRAMS; DISEASES; EVALUATION; INFORMATION