Published July 1983
| Version v1
Journal article
Obrigheim demonstrates efficacy of nuclear power stations
Description
The article describes the excellent performance of Obrigheim nuclear power station - this operates with a pressurized-water reactor - since it was first put into service 14 years ago. Tables showing the reasons for non-availability are included. The article also deals with updated safety measures introduced to bring the plant up to the latest state of the art and also the possibilities of extending the service life of nuclear power stations. (orig.)
Abstract (German)
Im Beitrag werden die guten Betriebsergebnisse des seit 14 Jahren betriebenen Druckwasserreaktors im Kernkraftwerk Obrigheim dargestellt. Nichtverfuegbarkeiten werden aufgeschluesselt. Weiterhin wird ueber die Anpassung an den fortschreitenden Stand der Sicherheitstechnik und ueber Moeglichkeiten der Verlaengerung der Lebensdauer von Kernkraftwerken berichtet. (orig.)Additional details
Additional titles
- Original title (German)
- Betriebsbewaehrung von Kernkraftwerken am Beispiel der Anlage Obrigheim
Publishing Information
- Journal Title
- Siemens Energietech.
- Journal Volume
- 5
- Journal Issue
- 4
- Series
- Siemens Energietech.
- Journal Page Range
- 221-224
- ISSN
- 0170-9496
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 15006864
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AVAILABILITY; ELECTRICAL EQUIPMENT; LIFETIME; OBRIGHEIM REACTOR; OPERATION; REACTOR COMPONENTS; REACTOR SAFETY; RETROFITTING; STEAM GENERATORS
- Descriptors DEC
- BOILERS; ENRICHED URANIUM REACTORS; EQUIPMENT; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SAFETY; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS