Published March 1992 | Version v1
Journal article

Safety protection and radiation monitoring in strong source relocation operation

  • 1. Shanghai Radiation Technology Popularization and Application Centre (China)

Description

This article describes the whole process, safety Measures and radiation monitoring in three strong source (3.7-7.9 x 1015 Bq) operations in 1986. The monitoring result are as follows: the maximum exposure rate on the surface of transportation plumbic-container is 17 mR/h. The highest dose equivalent that received by the operators at one operation is about 0.91 μSv. The monitoring value of pollution or leakage radioactivity from the cobalt element is 42 Bq/element which is lower than the ISO limit (185 Bq/element). After the source has been placed in the irradiation room, the exposure rate around the room is 17 μR/h

Additional details

Publishing Information

Journal Title
Radiation Protection (Taiyuan)
Journal Volume
11
Journal Issue
3
Journal Page Range
p. 216-221.
ISSN
1000-8187
CODEN
FUFAEM

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
24006765
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
DOSE RATES; IRRADIATION DEVICES; MATERIALS HANDLING; RADIATION MONITORING; RADIATION PROTECTION; RADIATION SOURCES; RADIOLOGICAL PERSONNEL; SECURITY
Descriptors DEC
MONITORING; PERSONNEL