Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time
Creators
- 1. Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium)
- 2. Department of Gynecology, Ghent University Hospital, Ghent (Belgium)
Description
Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 ± 2.5 min) than in supine position (19.4 ± 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2010.10.070Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2010.10.070;
- PII
- S0360-3016(10)03650-3;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 82
- Journal Issue
- 5
- Journal Page Range
- p. 2055-2064
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44016658
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CARCINOMAS; COMPUTERIZED TOMOGRAPHY; IRRADIATION; MAMMARY GLANDS; PATIENTS; RADIOTHERAPY; RESPIRATION; SCHEDULES; SENSORS; SURGERY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY
Optional Information
- Copyright