Published September 1, 2000
| Version v1
Report
Fuel Handling Exclusion Zone Established to Prevent Spurious Alarms to CAS Neutron Detectors in the IFSF
Description
An experimental and calculational study has been performed to understand and prevent inadvertent activation of the criticality alarm system (CAS) from fuel-handling operations at the Irradiated Fuel Storage Facility. In conjunction with the study, the CAS neutron detectors were tested to verify the design specifications for gamma rejection capability and zero response limit. A minimum physical restrictive boundary around the CAS location was established based on a gamma ray dose rate limit of 10 rad/hr. The canister loaded with spent nuclear fuel must be moved in the area outside the exclusion zone so as not to trigger a false alarm from the CAS detectors.
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- vp.
- Report number
- INEEL/CON--99-01337
Conference
- Title
- Radiation Protection and Shielding 2000 Topical Meeting
- Dates
- 17-21 Sep 2000
- Place
- Spokane, WA (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 39005045
- Subject category
- S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ALARM SYSTEMS; CONTAINERS; CRITICALITY; DESIGN; DOSE RATES; NEUTRON DETECTORS; NUCLEAR FUELS; RADIATION PROTECTION; SHIELDING; SPECIFICATIONS; SPENT FUELS; STORAGE
- Descriptors DEC
- ENERGY SOURCES; FUELS; MATERIALS; MEASURING INSTRUMENTS; NUCLEAR FUELS; RADIATION DETECTORS; REACTOR MATERIALS
Optional Information
- Contract/Grant/Project number
- AC07-99ID-13727
- Funding organization
- US Department of Energy (United States)