Published September 1, 2000 | Version v1
Report

Fuel Handling Exclusion Zone Established to Prevent Spurious Alarms to CAS Neutron Detectors in the IFSF

Description

An experimental and calculational study has been performed to understand and prevent inadvertent activation of the criticality alarm system (CAS) from fuel-handling operations at the Irradiated Fuel Storage Facility. In conjunction with the study, the CAS neutron detectors were tested to verify the design specifications for gamma rejection capability and zero response limit. A minimum physical restrictive boundary around the CAS location was established based on a gamma ray dose rate limit of 10 rad/hr. The canister loaded with spent nuclear fuel must be moved in the area outside the exclusion zone so as not to trigger a false alarm from the CAS detectors.

Additional details

Publishing Information

Imprint Pagination
vp.
Report number
INEEL/CON--99-01337

Conference

Title
Radiation Protection and Shielding 2000 Topical Meeting
Dates
17-21 Sep 2000
Place
Spokane, WA (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
39005045
Subject category
S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ALARM SYSTEMS; CONTAINERS; CRITICALITY; DESIGN; DOSE RATES; NEUTRON DETECTORS; NUCLEAR FUELS; RADIATION PROTECTION; SHIELDING; SPECIFICATIONS; SPENT FUELS; STORAGE
Descriptors DEC
ENERGY SOURCES; FUELS; MATERIALS; MEASURING INSTRUMENTS; NUCLEAR FUELS; RADIATION DETECTORS; REACTOR MATERIALS

Optional Information

Contract/Grant/Project number
AC07-99ID-13727
Funding organization
US Department of Energy (United States)