Published November 2002 | Version v1
Journal article

A method of water level detection in boiling water reactors using the 16N decay

  • 1. Dept. of Reactor Physics, Chalmers Univ. of Technology, Goeteborg (Sweden)

Description

An experimental simulation of water level detection in boiling water reactors is presented. The water in a vertical pipe was irradiated with fast neutrons produced by a neutron generator, whereby 16O was activated to 16N. Two BGO detectors along the pipe at two different heights measured the gamma radiation at different water levels. The 16N detection in a boiling water reactor could thus be simulated in an experimental set-up with a minimum of other sources. (orig.)

Additional details

Publishing Information

Journal Title
Kerntechnik (1987)
Journal Volume
67
Journal Issue
5-6
Journal Page Range
p. 296-298
ISSN
0932-3902
CODEN
KERNEU