Published January 5, 2004 | Version v1
Report

Measurement of the Tau Lepton Lifetime Using the SLD Detector at the Stanford Linear Collider

Description

The lifetime of the tau lepton is measured to be (2.50 ± 0.35) x 10-14s. The measurement combines the results of two different techniques used on separate samples of tau events collected at the Stanford Linear Collider by the SLD detector during the 1992 physics run. The first technique measures the decay length from the known interaction position to the reconstructed decay vertex position. This requires that the taus have at least three charged decay products. The second technique infers the decay length by correlating the differences in signed impact parameters (for single-charged track decays) with the angles between the tracks

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/826659-zMv95s/native/

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
SLAC-R--685

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
35087828
Subject category
S72: PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
DAUGHTER PRODUCTS; DECAY; IMPACT PARAMETER; LIFETIME; STANFORD LINEAR COLLIDER; TAU PARTICLES
Descriptors DEC
ACCELERATORS; ELEMENTARY PARTICLES; FERMIONS; HEAVY LEPTONS; ISOTOPES; LEPTONS; LINEAR ACCELERATORS; LINEAR COLLIDERS

Optional Information

Contract/Grant/Project number
AC03-76SF00515
Funding organization
USDOE Office of Science (United States)