Published February 1985 | Version v1
Journal article

Measurements of the electron temperature in the T-10 tokamak using carbon pellet injection

  • 1. Leningradskij Politekhnicheskij Inst. (USSR)

Description

Known methods for measuring electron temperature Tsub(e) in tokamaks such as the Thompson scattering, X-ray and SHF methods are not enough reliable in a peripheral zone either due to a low signal level or superhigh radiation nature. This promotes development of new methods for measuring temperature. This paper contains results of experiments on Tsub(e)(r) profiledetermination in the T-10 tokamak by injection of carbon microparticles at omic and SHF heating regimes. The technique described permitted to obtain Tsub(e)(r) profile in the range of particle evaporation during approximately 1-2 ms. The range of measured temperatures Tsub(e) amounted to 100-1000 eV. Experimental data are compared with Tsub(e)(r) values obtained by means of X ray diagnostics and diagnostics by radiation at the second harmonics of cyclotron frequency

Additional details

Additional titles

Original title (Russian)
Измерение температуры электронов в токамаке Т-10 с помощью инжекции углеродных макрочастиц

Publishing Information

Journal Title
Fiz. Plazmy
Journal Volume
12
Journal Issue
2
Series
Fiz. Plazmy.
Journal Page Range
131-137
ISSN
0367-2921
CODEN
FIPLD

Optional Information

Notes
For English translation see the journal Soviet Journal of Plasma Physics (USA).