Minimally invasive input function for 2-18F-fluoro-A-85380 brain PET studies
Creators
- 1. National Institute of Mental Health, NIH, Molecular Imaging Branch, Bethesda, MD (United States)
- 2. CEA, DSV, I2BM, Service Hospitalier Frederic Joliot, Orsay (France)
- 3. CEA, DSV, I2BM, NeuroSpin, Gif-sur-Yvette (France)
Description
Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-18F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF. Ten healthy volunteers underwent a dynamic 2-18F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (VT) values were compared to the reference values obtained from arterial cannulation. For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan VT ratio was 1.00 ± 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (VT ratio 1.03 ± 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (VT ratio 1.13 ± 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples. PBIF scaled with arterial samples accurately estimates Logan VT for 2-18F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration differences, venous samples cannot be substituted for arterial samples. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00259-011-2004-9Additional details
Identifiers
Publishing Information
- Journal Title
- European Journal of Nuclear Medicine and Molecular Imaging
- Journal Volume
- 39
- Journal Issue
- 4
- Journal Page Range
- p. 651-659
- ISSN
- 1619-7070
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43056598
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACETYLCHOLINE; BLOOD CHEMISTRY; BRAIN; CAROTID ARTERIES; COMPUTERIZED TOMOGRAPHY; CONCENTRATION RATIO; FLUORINE 18; LIGANDS; METABOLITES; NMR IMAGING; POSITRON COMPUTED TOMOGRAPHY; RADIOPHARMACEUTICALS; RECEPTORS; TIME DEPENDENCE; TRACER TECHNIQUES
- Descriptors DEC
- AMMONIUM COMPOUNDS; ARTERIES; AUTONOMIC NERVOUS SYSTEM AGENTS; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BIOCHEMISTRY; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CENTRAL NERVOUS SYSTEM; CHEMISTRY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DRUGS; EMISSION COMPUTED TOMOGRAPHY; ESTERS; FLUORINE ISOTOPES; HOURS LIVING RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPE APPLICATIONS; ISOTOPES; LABELLED COMPOUNDS; LIGHT NUCLEI; MATERIALS; MEMBRANE PROTEINS; NANOSECONDS LIVING RADIOISOTOPES; NERVOUS SYSTEM; NEUROREGULATORS; NUCLEI; ODD-ODD NUCLEI; ORGANIC COMPOUNDS; ORGANS; PARASYMPATHOMIMETICS; PROTEINS; QUATERNARY AMMONIUM COMPOUNDS; RADIOACTIVE MATERIALS; RADIOISOTOPES; TOMOGRAPHY