Published April 1976
| Version v1
Report
Open
Analysis of ultrasonic inspection data for Pilgrim 1 Reactor Nozzle N-2B
Description
The ultrasonic examination data relative to the discontinuity located in the pilgrim I reactor Vessel Nozzle N-2B weld was reviewed. The data was obtained during the 1976 in-service inspection. The results of the review of several examinations are tabulated, test conditions discussed, and a conclusion made as to probable flaw size
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01.Files
8343904.pdf
Files
(527.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:348f0cc0d656b1a0a00abc374ebd3b77
|
527.1 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 19 p.
- Report number
- ORNL/TM--5912
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8343904
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- DEFECTS; INSPECTION; NOZZLES; PILGRIM-1 REACTOR; PRESSURE VESSELS; ULTRASONIC TESTING; WELDED JOINTS
- Descriptors DEC
- ACOUSTIC TESTING; CONTAINERS; ENRICHED URANIUM REACTORS; JOINTS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; POWER REACTORS; PWR TYPE REACTORS; REACTORS; TESTING; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS