Published January 1983 | Version v1
Journal article

Radioimmunoassay of sodium cromoglycate in human plasma

  • 1. Fisons plc, Loughborough (UK). Pharmaceutical Div.

Description

A sensitive radioimmunoassay method for sodium cromoglycate in human plasma is described. The lowest quantifiable concentration of sodium cromoglycate is 0.93 nmol/l when 0.1 ml plasma samples are analysed. The range of the method is limited; both 0.01 and 0.1 ml volumes of plasma must be analysed to encompass the concentration range 0.93-139 nmol/l which may be encountered in plasma samples from patients and human volunteers. The method is specific for sodium cromoglycate as indicated by a low cross-reactivity of the anti-cromoglycate antiserum with a number of drugs. (author)

Additional details

Publishing Information

Journal Title
Ann. Clin. Biochem.
Journal Volume
20
Journal Issue
pt.1
Series
Ann. Clin. Biochem.
Journal Page Range
31-36
ISSN
0004-5632