Published 2009 | Version v1
Miscellaneous

Effect of solution treatment on Mg galvanic anodes in CaSo4-Mg (OH)2 aqueous solution

  • 1. School of Materials Engineering, Universiti Malaysia Perlis, Jejawi, Arau, Perlis (Malaysia)
  • 2. Science and Technology Research for Defence (STRIDE), Loakis 19, Bousted Naval Shipyard Sdn. Bhd., Pangkalan TLDM, Lumut, Perak (Malaysia)

Description

The effect of heat treatment on the Mg anode was investigated in CaSO4-Mg(OH)2 aqueous solution. The Mg sample was solutionised at 150 degree Celsius, pure and untreated Mg anodes were also studied as a reference. EOC and Tafel corrosion rate was determined by mean of potentiostat. It was found that solution treatment was significantly affecting the performance of Mg anode where it EOC was electro negatively increases to -1.6404 VSCE and the Tafel corrosion rate reduces to 12.23 mpy. (author)

Availability note (English)

Available in Malaysian Nuclear Agency Document Delivery Center by email: mohdhafizal@nuclearmalaysia.gov.my. Also available in Malaysian Nuclear Agency library.

Additional details

Publishing Information

Imprint Pagination
5 p.

Conference

Title
Malaysia International NDT Conference and Exhibition '09
Acronym
MINDTCE 09
Dates
20-21 Jul 2009
Place
Kuala Lumpur (Malaysia)

INIS

Country of Publication
Malaysia
Country of Input or Organization
Malaysia
INIS RN
42005356
Subject category
S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ANODES; AQUEOUS SOLUTIONS; CORROSION; ELECTROCHEMICAL CORROSION; ELECTRONEGATIVITY; HEAT TREATMENTS; MAGNESIUM
Descriptors DEC
ALKALINE EARTH METALS; CHEMICAL REACTIONS; CORROSION; DISPERSIONS; ELECTRODES; ELEMENTS; HOMOGENEOUS MIXTURES; METALS; MIXTURES; SOLUTIONS

Optional Information

Notes
Poster presentation. Published in proceeding 'NDT Driving Industry Safety, Growth and Performance'. 263 p.p. 176-180