Published August 1986 | Version v1
Journal article

Development of a combined algorithm of on-line instrument failure detection with an improved generalized likelihood ratio method and suboptimal control on a PWR pressurizer

  • 1. Korea Advanced Institute of Science and Technology, Dept. of Nuclear Engineering, P.O. Box 150, Chongryang, Seoul

Description

In nuclear power plants, instrument failures must be detected and compensated for before a significant decrease in plant performance occurs. The improved generalized likelihood ratio method to detect and identify a failure and a control algorithm in the event of an instrument failure is developed. The failure detection algorithm and the control algorithm are combined and applied to a pressurized water reactor pressurizer. Computer simulation tests show that on-line prompt failure detection and compensation through control action can be performed very successfully even when there is an instrument failure

Additional details

Publishing Information

Journal Title
Nucl. Technol.
Journal Volume
74
Journal Issue
2
Series
Nucl. Technol.
Journal Page Range
113-131
ISSN
0029-5450
CODEN
NUTYB