Evaluation of left ventricular and left atrial volumetric function from native MR multislice 4D flow magnitude data
Creators
- 1. Division of Cardiology, Department of Internal Medicine, Medical University of Graz, Graz (Austria)
- 2. Division of Neuroradiology, Vascular and Interventional Radiology, Department of Radiology, Medical University of Graz, Graz (Austria)
- 3. Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9/P, 8036, Graz (Austria)
- 4. Research and Development, Siemens Healthcare Diagnostics GmbH, Graz (Austria)
Description
To assess the feasibility, precision, and accuracy of left ventricular (LV) and left atrial (LA) volumetric function evaluation from native magnetic resonance (MR) multislice 4D flow magnitude images. In this prospective study, 60 subjects without signs or symptoms of heart failure underwent 3T native cardiac MR multislice 4D flow and bSSFP-cine realtime imaging. LV and LA volumetric function parameters were evaluated from 4D flow magnitude (4D flow-cine) and bSSFP-cine data using standard software to obtain end-diastolic volume (EDV), end-systolic volume (ESV), ejection-fraction (EF), stroke-volume (SV), LV muscle mass (LVM), LA maximum volume, LA minimum volume, and LA total ejection fraction (LATEF). Stroke volumes derived from both imaging methods were further compared to 4D pulmonary artery flow-derived net forward volumes (NFV). Methods were compared by correlation and Bland-Altman analysis. Volumetric function parameters from 4D flow-cine and bSSFP-cine showed high to very high correlations (r = 0.83-0.98). SV, LA volumes and LATEF did not differ between methods. LV end-diastolic and end-systolic volumes were slightly underestimated (EDV: -2.9 ± 5.8 mL; ESV: -2.3 ± 3.8 mL), EF was slightly overestimated (EF: 0.9 ± 2.6%), and LV mass was considerably overestimated (LVM: 39.0 ± 11.4 g) by 4D flow-cine imaging. SVs from both methods correlated very highly with NFV (r = 0.91 in both cases) and did not differ from NFV. Native multislice 4D flow magnitude data allows precise evaluation of LV and LA volumetric parameters; however, apart from SV, LV volumetric parameters demonstrate bias and need to be referred to their respective normal values. Volumetric function assessment from native multislice 4D flow magnitude images can be performed with routinely used clinical software, facilitating the application of 4D flow as a one-stop-shop functional cardiac MR exam, providing consistent, simultaneously acquired, volume and flow data.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 34
- Journal Issue
- 2
- Journal Page Range
- p. 981-993
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55034849
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ARTERIES; BIOLOGICAL FUNCTIONS; BLOOD CIRCULATION; COMPARATIVE EVALUATIONS; COMPUTER CODES; CORRELATIONS; DATA COMPILATION; FOUR-DIMENSIONAL CALCULATIONS; HEART; HEART FAILURE; IMAGE PROCESSING; MUSCLES; SCATTERPLOTS; VALIDATION
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DATA; DATA PROCESSING; DIAGRAMS; EVALUATION; INFORMATION; ORGANS; PROCESSING; SYMPTOMS; TESTING