Published 2007 | Version v1
Journal article

Treating voxel geometries in radiation protection dosimetry with a patched version of the Monte Carlo codes MCNP and MCNPX

  • 1. ENEA-Italian National Agency for Energy, New Technologies and the Environment, FIS-NUC, V.M.M. Sole 4, 40129 Bologna (Italy)
  • 2. INOA-Italian National Inst. for Applied Optics, Largo E Fermi 6, 50125 Firenze (Italy)
  • 3. ENEA-Italian National Agency for Energy, New Technologies and the Environment, BAS-ION-IRP, V. dei Colli 16, 40136 Bologna (Italy)
  • 4. IOR, Rizzoli Hospital, IT Service, Salita S.Benedetto 1, 40136 Bologna (Italy)

Description

The question of Monte Carlo simulation of radiation transport in voxel geometries is addressed. Patched versions of the MCNP and MCNPX codes are developed aimed at transporting radiation both in the standard geometry mode and in the voxel geometry treatment. The patched code reads an un-formatted FORTRAN file derived from DICOM format data and uses special subroutines to handle voxel-to-voxel radiation transport. The various phases of the development of the methodology are discussed together with the new input options. Examples are given of employment of the code in internal and external dosimetry and comparisons with results from other groups are reported. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncl150

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
123
Journal Issue
3
Journal Page Range
p. 345-353
ISSN
0144-8420

Optional Information

Notes
46 refs