Published April 2009 | Version v1
Report Open

Technology study on determination of Sr in environmental water samples using ICP-AES method

  • 1. China Academy of Engineering Physics, Mianyang (China). Inst. of Nuclear Physics and Chemistry

Description

It is necessary to establish a rapid method for determination of Sr in order to accurately calculate chemical recovery in determination of 90Sr. Determination of Sr in environmental water samples by ICP-AES method was studied in the paper. In the optimum condition, detection limit of the method is 0.000 6 mg/ L, relative standard deviation is less than 3%, recoveries differ from 90.17% to 108.0%. The results show that the method can meet the need of determination of Sr in environmental water samples and apply to substract Sr background content in radiochemical analysis for 90Sr. (authors)

Files

41127857.pdf

Files (651.9 kB)

Name Size Download all
md5:f5fbbcca9dd33023a9aa214374e4fb7c
651.9 kB Preview Download

Additional details

Publishing Information

ISBN
978-7-5022-4474-3
Imprint Pagination
6 p.
Report number
CNIC--01976

Optional Information

Notes
3 figs., 3 tabs., 8 refs.