Published December 2004 | Version v1
Journal article

The effect of an aggressive cool-dowm following a refueling outage accident in which a pressurizer safety valve is stuck open

  • 1. KAERI, Taejon (Korea, Republic of)

Description

A PSV(Pressurizer Safety Valve) popping test carried out in the early phases of a refueling outage may trigger a test-induced LOCA(Loss Of Coolant Accident) if a PSV fails to fully close and is stuck in a partially open position. According to a KSNP(Korea Standard Nuclear Power Plant) low power and shutdown PSA(Probabilistic Safety Assessment), the failure of a High Pressure Safety Injection (HPSI) accompanied by the failure of a PSV to fully close was identified as a dominant accident sequence with a significant impact on Low Power and Shutdown Risks (LPSR). In this study, we aim to investigate and verity a new means for mitigating this type of accident using a thermal-hydraulic analysis. In particular, we explore the applicability of an aggressive cool-down combined with operator actions. The results of the various sensitivity studies performed here will help reduce LPSR and improve refueling outage safety

Additional details

Publishing Information

Journal Title
Journal of the Korean Nuclear Society
Journal Volume
36
Journal Issue
6
Series
26 refs, 9 figs, 1 tab
Journal Page Range
p. 497-511
ISSN
0372-7327
CODEN
WJHKAW