Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems
Creators
- 1. Universitaetsklinik Bonn, Radiologische Klinik, FE Strahlentherapie, Bonn (Germany)
Description
Patient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. Thirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal registered or Open Face registered mask, Orfit) or the standard three-point mask (Raycast registered -HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation. The mean values of the table adjustments were: (a) lateral (mm): -0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); -0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): -1 (mask 1, σ: 2.57); -0.5 (mask 2, σ: 4.7); -1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35 (mask 1, σ: 0.75); 0 (mask 2, σ: 0.8); 0.02 (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5 (roll). There were no significant differences between the groups. The new mask systems improve patient comfort while providing consistent patient positioning. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00066-013-0496-xAdditional details
Identifiers
Publishing Information
- Journal Title
- Strahlentherapie und Onkologie
- Journal Volume
- 190
- Journal Issue
- 4
- Journal Page Range
- p. 382-385
- ISSN
- 0179-7158
- CODEN
- STONE4
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 45049422
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; CEREBRUM; COMPUTERIZED TOMOGRAPHY; CT-GUIDED RADIOTHERAPY; FRACTIONATED IRRADIATION; GY RANGE 10-100; HEAD; MASKING; NECK; PATIENTS; POSITIONING; RADIATION DOSES; RADIATION PROTECTION; SAFETY MARGINS; THERMOPLASTICS
- Descriptors DEC
- ABSORBED DOSE RANGE; BODY; BRAIN; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; GY RANGE; IRRADIATION; MATERIALS; MEDICINE; NEOPLASMS; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANIC COMPOUNDS; ORGANIC POLYMERS; ORGANS; PETROCHEMICALS; PETROLEUM PRODUCTS; PLASTICS; POLYMERS; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; SYNTHETIC MATERIALS; THERAPY; TOMOGRAPHY