Published October 2007 | Version v1
Journal article

Noble-gas liquid detectors: measurement of light diffusion and reflectivity on commonly adopted inner surface materials

  • 1. Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pavia, via A. Bassi 6, I-27100 Pavia (Italy)
  • 2. Dipartimento di Fisica Nucleare e Teorica (DFNT), via A. Bassi 6, I-27100 Pavia (Italy)

Description

Noble-gas liquids, such as xenon and argon, have been recently proposed as Vacuum Ultra Violet (VUV) light scintillators in some experiments dedicated to neutrino physics and dark matter research. Fundamental parameters for the photon detection are the diffusion coefficient and the reflectivity of the materials that surround the active volume of the apparatus. We carried out a investigation on the most commonly used materials at the scintillation wavelength λ∼172 nm (close to the liquid xenon wavelength). The measurement has been performed at various incident angles by means of a collimated VUV source. The experimental set-up and the results obtained at room temperature with stainless steel, aluminum, peek and teflon targets are presented

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nuclphysbps.2007.08.059

Additional details

Identifiers

DOI
10.1016/j.nuclphysbps.2007.08.059;
PII
S0920-5632(07)00609-3;

Publishing Information

Journal Title
Nuclear Physics. B, Proceedings Supplements
Journal Volume
172
Journal Page Range
p. 260-262
ISSN
0920-5632
CODEN
NPBSE7

Conference

Title
10. topical seminar on innovative particle and radiation detectors
Dates
1-5 Oct 2006
Place
Siena (Italy)

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.