Published October 2015 | Version v1
Journal article

Mobile 950 keV/3.95 MeV X-band electron linac X-ray sources and industrial/societal infrastructure inspection

  • 1. Tokyo Univ., Tokyo (Japan)
  • 2. National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki (Japan)
  • 3. Accuthera Inc., Kawasaki, Kanagawa (Japan)
  • 4. Hitachi Power Solutions Co., Ltd., Hitachi, Ibaraki (Japan)
  • 5. Mitsubishi Chemical Corp., Tokyo (Japan)
  • 6. Public Works Research Institute, Tsukuba, Ibaraki (Japan)

Description

We have developed portable X-band (9.3 GHz) 950 keV/3.95 MeV linac X-ray sources. We are applying the 950 keV system for nondestructive testing testing of industrial and societal infrastructures such as reaction tower, pier and bridge (thinner than 400 mm). Not only the inner structure, but also dynamic image of the inner fluid can be obtained. We have joined the benchmark test for cut samples of a real bridge with other NDT methods hosted by National Institute of Land and Infrastructure Management. We have successfully performed 3.95 MeV electron linac X-ray inspection of bridge sample at Public Works Research Institute for the first time in Japan. We use flat-panel X-ray camera, imaging plate, partial angle CT and Tomosynthesis so that iron-wires of 7 mm diameter can be reconstructed with 1 mm spatial resolution. (author)

Additional details

Publishing Information

Journal Title
Kasokuki
Journal Volume
12
Journal Issue
3
Journal Page Range
p. 142-151
ISSN
1349-3833

Optional Information

Notes
9 refs., 19 figs., 1 tab.