Published September 1, 2019 | Version v1
Journal article

Comparative Research on Anti-Seismic Test for FPB and Ordinary Spherical bearing

  • 1. ZhuZhou Times New Material Technology Co., Ltd., Zhuzhou, Hunan, 412007 (China)
  • 2. Highway Administration Bureau of Guizhou Province, Guiyang 550081 (China)
  • 3. Guizhou Transportation Planning Survey and Design Academe Co. Ltd., Guiyang 550081 (China)

Description

In this paper, a two-span-32m-simply supported girder bridge is studied. The Anti-seismic experiments are conducted for two groups of two-span bridges of low pier and middle pier based on a bridge model, 1/7 large of the real bridge established by principle of similitude. The impacts of three different seismic oscillations on the seismic response(displacement of bearings, internal force of piers and etc.) of simply supported beams of ordinary spherical bearings and FPBs under 7,8 and 9 intensities are discussed. The damage under different seismic oscillations are made clear and the study shows that FPBs boast of good Anti-seismic performance under near seismic oscillations of different levels and are more suitable for low pier structures. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1755-1315/304/4/042018

Additional details

Publishing Information

Journal Title
IOP Conference Series: Earth and Environmental Science (Online)
Journal Volume
304
Journal Issue
4
Journal Page Range
[6 p.]
ISSN
1755-1315

Conference

Title
International Conference on Civil and Hydraulic Engineering
Dates
10-12 May 2019
Place
Nanjing (China)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
53068833
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAMS; BRIDGES; CIVIL ENGINEERING; OSCILLATIONS; PERFORMANCE; SEISMICITY; SPHERICAL CONFIGURATION
Descriptors DEC
CONFIGURATION; ENGINEERING; MECHANICAL STRUCTURES