Published April 2020 | Version v1
Book

Countermeasure of FAC problem in PWR nuclear power plant

Creators

  • 1. East China Branch of China Nuclear Power Engineering Co., Ltd., Haiyan (China)

Description

This paper mainly discusses the problem of FAC (Flow Action Corrosion) in the secondary loop system of a PWR nuclear power plant. The mechanism of FAC and the influencing factors of FAC are given. The latest progress in the management of FAC and the example of FAC in foreign countries are introduced. The reasons for thinning the wall of the second loop of a PWR nuclear power plant are analyzed. At last, the preventive measures taken by the FAC of PWR nuclear power plant are put forward. These preventive measures have been applied to a nuclear power plant and achieved good results. (author)

Part of:
Progress report on nuclear science and technology in China (Vol.6). Proceedings of academic annual meeting of China Nuclear Society in 2019, No.3--Nuclear Energy and Power sub-volume

Additional details

Publishing Information

Publisher
China Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5221-0522-2
Imprint Title
Progress report on nuclear science and technology in China (Vol.6). Proceedings of academic annual meeting of China Nuclear Society in 2019, No.3--Nuclear Energy and Power sub-volume
Imprint Pagination
527 p.
Journal Page Range
p. 144-154

Conference

Title
2019 academic annual meeting of China Nuclear Society
Dates
20-23 Aug 2019
Place
Baotou (China)

Optional Information

Notes
8 figs., 2 tabs., 4 refs.