Published May 2001 | Version v1
Miscellaneous

Evaluation of irradiation behaviour of DUPIC pellets using the HANARO

  • 1. KAERI, Taejon (Korea, Republic of)

Description

The irradiation test of DUPIC pellets in the HANARO was carried out to estimate their in-pile behaviour and performance. For the irradiation period of 2 months, the maximum linear power calculated from the operational data of the HANARO was 59.12 kW/m, and the estimated average burnup of DUPIC pellets was 1,770 MWd/tU. These irradiated mini-elements were transported to the PIEF so that the post irradiation examinations such as metallography and γ-scanning was performed. The qualitative irradiation behaviour of DUPIC pellets in the HANARO can be estimated from the burnup history and the results of post irradiation examinations

Part of:
Proceedings of the Korean Nuclear Society spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Nuclear Society spring meeting
Imprint Pagination
[ONE CDROM]
Journal Page Range
[8 p.]

Conference

Title
2001 spring meeting of the Korean Nuclear Society
Dates
24-25 May 2001
Place
Cheju (Korea, Republic of)

Optional Information

Notes
12 refs, 4 figs, 2 tabs