Published June 2017 | Version v1
Journal article

Comparison of volumetric modulated arc therapy and non-coplanar fixed-field intensity modulated radiation therapy for irregular target adjacent to organ at risk

  • 1. Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

Description

The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans PTV100%=95%. The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Radiotherapeutic Technology
Journal Volume
29
Journal Issue
1
Series
21 refs, 8 figs, 6 tabs
Journal Page Range
p. 57-68
ISSN
1598-8449

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
49067577
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BRAIN; EFFICIENCY; HAZARDS; MONITORS; NERVES; PATIENTS; PLANNING; RADIATION DOSES; RADIOTHERAPY; SHAPE
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; DOSES; MEASURING INSTRUMENTS; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY