Published December 4, 2006 | Version v1
Journal article

A Simple Method For The Time-Resolved Measurement Of Electron Temperature In A Z-pinch

  • 1. Depto. Energia, Universidad Autonoma Metropolitana, Av. San Pablo 180, Azcapotzalco, 02200 Mexico City (Mexico)

Description

A new method for measuring the electron temperature in a Z-pinch plasma with time resolution is presented here. PIN diodes fitted with different filters were employed to detect the X-radiation in separate energy bands. By comparison of the relative intensities of the X-ray pulses, a time-resolved measurement of the electron temperature can be obtained. The first step of the implementation of the method consists in convoluting a continuum spectrum with the filter-detector response to estimate individual signal strength. The second step is to calculate the ratio of the amplitudes of 2 differently-filtered diodes as a function of temperature to obtain a temperature calibration. When the computed calibration is then compared with the experimental signal ratio the temperature can be obtained. The temperatures measured using the present method were found to have peak values from 3 to 7 keV. The method only applies when the plasma is emitting continuum radiation

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
875
Journal Issue
1
Journal Page Range
p. 27-30
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
16. IAEA technical meeting on research using small fusion devices; 11. Latin American workshop on plasma physics
Dates
30 Nov - 3 Dec 2005; 5-9 Dec 2005
Place
Mexico City (Mexico)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38060989
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; ELECTRON TEMPERATURE; FILTERS; LINEAR Z PINCH DEVICES; PLASMA; PLASMA DIAGNOSTICS; SIGNALS; TEMPERATURE DEPENDENCE; TEMPERATURE MEASUREMENT; TIME RESOLUTION; X RADIATION
Descriptors DEC
ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; LINEAR PINCH DEVICES; OPEN PLASMA DEVICES; PINCH DEVICES; RADIATIONS; RESOLUTION; THERMONUCLEAR DEVICES; TIMING PROPERTIES

Optional Information

Notes
(c) 2006 American Institute of Physics