A Simple Method For The Time-Resolved Measurement Of Electron Temperature In A Z-pinch
Creators
- 1. Depto. Energia, Universidad Autonoma Metropolitana, Av. San Pablo 180, Azcapotzalco, 02200 Mexico City (Mexico)
Description
A new method for measuring the electron temperature in a Z-pinch plasma with time resolution is presented here. PIN diodes fitted with different filters were employed to detect the X-radiation in separate energy bands. By comparison of the relative intensities of the X-ray pulses, a time-resolved measurement of the electron temperature can be obtained. The first step of the implementation of the method consists in convoluting a continuum spectrum with the filter-detector response to estimate individual signal strength. The second step is to calculate the ratio of the amplitudes of 2 differently-filtered diodes as a function of temperature to obtain a temperature calibration. When the computed calibration is then compared with the experimental signal ratio the temperature can be obtained. The temperatures measured using the present method were found to have peak values from 3 to 7 keV. The method only applies when the plasma is emitting continuum radiation
Additional details
Identifiers
- DOI
- 10.1063/1.2405897;
Publishing Information
- Journal Title
- AIP Conference Proceedings
- Journal Volume
- 875
- Journal Issue
- 1
- Journal Page Range
- p. 27-30
- ISSN
- 0094-243X
- CODEN
- APCPCS
Conference
- Title
- 16. IAEA technical meeting on research using small fusion devices; 11. Latin American workshop on plasma physics
- Dates
- 30 Nov - 3 Dec 2005; 5-9 Dec 2005
- Place
- Mexico City (Mexico)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38060989
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; ELECTRON TEMPERATURE; FILTERS; LINEAR Z PINCH DEVICES; PLASMA; PLASMA DIAGNOSTICS; SIGNALS; TEMPERATURE DEPENDENCE; TEMPERATURE MEASUREMENT; TIME RESOLUTION; X RADIATION
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; LINEAR PINCH DEVICES; OPEN PLASMA DEVICES; PINCH DEVICES; RADIATIONS; RESOLUTION; THERMONUCLEAR DEVICES; TIMING PROPERTIES
Optional Information
- Notes
- (c) 2006 American Institute of Physics