Published 1978 | Version v1
Miscellaneous Restricted

Gamma spectrometric determination of 237Np in PUREX-process solutions

  • 1. Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Heisse Chemie

Description

Because of its low-energetic intrinsic radiator 237Np can be determined by γ-spectroscopy with semi conduting detectors after selective separation by TTA-extraction from process solution. Under realistic conditions the sensivity limit is about 0.1 μg 237Np/ml. This method, which has been developed for process analytic purposes has a lower rate of failure compared to conventional α-spectrometry and is fast than activation analysis. (orig.)

Availability note (English)

MF available from INIS under the Report Number.

Abstract (German)

Durch Halbleiter-Gammaspektrometrie laesst sich 237Np aufgrund seiner niederenergetischen Eigenstrahlung bestimmen, nachdem es zuvor durch TTA-Extraktion aus den Prozessloesungen selektiv abgetrennt worden ist. Die Bestimmungsgrenze liegt unter realistischen Messbedingungen bei 0,1 μg 237Np/ml. Diese fuer prozessanalytische Zwecke entwickelte Methode ist weniger stoeranfaellig als die gebraeuchliche α-Spektrometrie und schneller als die Aktivierungsanalyse. (orig.)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (German)
Gammaspektrometrische Bestimmung von

Publishing Information

Imprint Pagination
11 p.
Report number
AED-Conf--78-274-022

Conference

Title
Lecture meeting on principles and applications of nuclear-, radio-, and radiation chemistry.
Dates
16 - 19 Oct 1978.
Place
Lindau, Germany, F.R.